DS 500 mobile

analysis according to DIN EN 50001Energy analysis – consumption measurement – leakage calculation at compressed airsystems

Description

Intelligent mobile chart recorder – DS 500 mobile
If we talk about operational costs of compressed air plants we are actually talking about the energy costs as they make up about 70 to 80 % of the total costs of a compressed air plant. Depending on the size of the plant this means considerable operating costs. Even in smaller plants this may quickly add up to 10 000 to 20 000 € per year. This is an amount which can be considerably reduced – even in case of well operated and maintained plants. For sure this also applies to your compressed air plant! Which actual costs per generated m³ air do you actually have? Which energy is gained due to the waste heat recovery? What is the total performance balance of your plant? How high are the differential pressures of single filters? How high is the humidity (pressure dew point)? How much compressed air is used? By means of the intelligent chart recorder DS 500 mobile and the suitable sensors and meters all these questions can be answered easily. For example by means of a long-term measurement over 7 days, data recording and evaluation at the PC.

The intelligent chart recorder of the future – energy analysis according to DIN EN 50001 Energy analysis – consumption measurement – leakage calculation at compressed air systems

Your advantages of DS 500 mobile at a glance
• Easy and clear layout: Very easy operation via 7″ color display with touch panel
• Versatile: Up to 12 sensors/meters connectable also third-party sensors/meters including power supply
• Reliable: Stores all measured values on a memory card, easy reading-out via USB stock possible
• Intelligent energy analysis: Daily/weekly/monthly evaluations mathematic function for internal calculations, e.g. the typical key data of a compressed air plant

Typical key data of a compressed air plant:
• costs in € per generated m³ air
• kWh/m³ generated air
• flow of single lines including summation

  TECHNICAL DATA DS 500 MOBILE
  Case dimensions   360 x 270 x 150 mm
  Weight   4.5 kg
  Material   Diecast, front foil polyester, ABS
  Sensor inputs   4/8/12 sensor inputs for analogueue and digital sensors; freely allocatable.
  Digital CS sensors for dew point and consumption with FA/VA series SDI interface,
  Digital CS sensors for dew point and flow with SDI interface FA/VA series
  digital third-party sensors RS485 / Modbus RTU. Analogue CS Sensors for pressure
  temperature, clamp-on ammeters preconfigured.
  Analogue third-party sensors 0/4...20 mA, 0...1/10/30 V, pulse, Pt 100 / Pt 1000, KTY, counter
  Voltage supply for sensors   24 VDC, max. 130 mA per sensor, integrated mains unit, max. 24 VDC, 25 W
  For version 8/12 sensor inputs 2 integrated mains units, each max. 24 VDC, 25 W
  Interfaces   USB stick, Ethernet / RS 485 Modbus RTU / TCP, SDI other bus systems on request
  webserver optionally, GSM module
  Memory card   Micro SD memory card, memory size 8 GB
  Power supply   100…240 VAC, 50-60 Hz
  Colour display   7" touch panel TFT transmissive, graphics, curves, statistics
  Accuracy   Please see sensor specifications
  Operating temperature:   0…50° C
  Storage temperature:   -20…70° C

เอกสารข้อมูลผลิตภัณฑ์